Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Tex Heart Inst J ; 49(4)2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-36018783

RESUMO

Aberrant right subclavian artery is a common aortic arch anomaly that can cause dysphagia as a result of compression by the aberrant artery. For patients with an aneurysm associated with an aberrant right subclavian artery, surgical or endovascular intervention is a well-described treatment. However, for patients with a nonaneurysmal aberrant right subclavian artery, treatment with thoracic endovascular aortic repair has been limited. We describe the use of thoracic endovascular aortic repair and subclavian revascularization to treat esophageal stricture in a patient with a symptomatic nonaneurysmal aberrant right subclavian artery. The patient's dysphagia was successfully relieved after the operation.


Assuntos
Aneurisma da Aorta Torácica , Anormalidades Cardiovasculares , Transtornos de Deglutição , Procedimentos Endovasculares , Aorta Torácica , Humanos , Artéria Subclávia/anormalidades
2.
Ann Vasc Surg ; 78: 170-179, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34474131

RESUMO

BACKGROUND: To report technical and clinical 30-day results following treatment with the Zenith Alpha™ abdominal stent graft from the ZEnith alPHa for aneurYsm Repair Registry (ZEPHYR). METHODS: Multicenter, nonrandomized, single arm, core laboratory-controlled, prospective registry collecting data on the Zenith Alpha Abdominal Endovascular Graft being used in subjects with abdominal aortic aneurysms (AAA) from sites in Germany, Belgium, and The Netherlands between December 2016 and December 2019. Inclusion criteria were non-ruptured AAAs with a maximum diameter ≥50 mm or enlargement >5 mm over 6 months with an AAA neck length ≥10 mm (site reported). Primary outcome measure was treatment success at 30 days. Treatment success was defined as a combined endpoint consisting of technical and clinical success. Technical success was defined as successful stent graft delivery and deployment as well as successful removal of the delivery system. Clinical success at 30 days was defined as freedom from type I and III endoleak, aneurysm rupture, conversion to open surgery and stent graft occlusion. RESULTS: Three hundred forty-seven subjects were included from 14 sites with a median age of 73.0 years (IQR 68.0-79.0). Thirty-four patients were female (9.8%). The median AAA diameter was 58.3 mm (IQR 55.0-63.5). The median proximal neck diameter was 23.6 mm (IQR 22.0-25.2) with a median proximal neck length of 24.4 mm (IQR 15.0-34.8) and a median infrarenal neck angulation of 24.5° (IQR 15.0-35.0). The right and left common iliac diameter were 16.1 mm (IQR 14.1-19.4) and 16.2 mm (IQR 14.1-19.1), respectively. The treatment success rate at 30 days was 94.8% (N = 329). Technical success was achieved in 333 patients (96.0%). The clinical success rate at 30 days was 98.8% (N = 343). Three patients had limb occlusions at 30 day follow up (0.9%). One patient had a type Ib endoleak (0.3%). Seventy percent of vascular access approaches were percutaneous. The reintervention rate was 1.7% (N = 6) within 30 days. Indications for reinterventions were a false aneurysm at puncture site (N = 1), limb complications (N = 2), stentgraft-associated renal artery occlusions (N = 2), and an external iliac artery thrombosis (N = 1). CONCLUSIONS: Endovascular aneurysm repair using the Zenith Alpha Abdominal Endovascular Graft is effective in the short term. Long term results will be reported in the future.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Procedimentos Endovasculares/métodos , Idoso , Idoso de 80 Anos ou mais , Aneurisma Roto , Conversão para Cirurgia Aberta , Endoleak , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Sistema de Registros , Stents
3.
Rev. argent. cardiol ; 88(5): 434-439, set. 2020. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1251017

RESUMO

RESUMEN Introducción: Los aneurismas de aorta siguen siendo una patología frecuente, en especial aquellos localizados en la aorta abdominal. Desde 1990, gracias al avance en los dispositivos y las técnicas endovasculares, la cirugía convencional ha dejado de ser la única opción de tratamiento. Presentamos nuestros resultados en el manejo del aneurisma de aorta con técnica endovascular mínimamente invasiva. Objetivos: Analizar los resultados a 30 días del implante de endoprótesis en la aorta torácica y abdominal con una estrategia mínimamente invasiva. Material y métodos: Entre marzo de 2012 y abril de 2019 se realizaron 395 implantes consecutivos de endoprótesis de aorta; en 264 (67%) de los cuales se utilizó una técnica mínimamente invasiva (MIN-A). De este grupo 240 procedimientos (90,9%) fueron llevados a cabo para reparar la aorta abdominal (EVAR) y 24 (9,1%) la aorta torácica (TEVAR). Resultados: De 264 pacientes se logró éxito técnico (ET) del implante en el 99,6% y éxito clínico (EC) en el 97,7%. La mortalidad a 30 días fue del 1,1% dado por neumonía, insuficiencia cardíaca y EPOC. Ningún paciente presentó IAM, ACV o necesitó de conversión a reparación quirúrgica de urgencia. El tiempo promedio del procedimiento fue de 62 minutos (SD ± 17). Algunos pacientes requirieron conversión a cierre quirúrgico del acceso [20 (7%) durante los primeros 100 casos, y 7 (3%) en los últimos 164 pacientes p = 0,05)]. El sangrado mayor que requirió transfusión fue del 1,1%. El tiempo promedio para la deambulación fue de 18 horas (SD ± 10), que luego de los primeros 100 pacientes disminuyó en forma significativa a 13 horas (SD ± 2,9 p = 0,05). La estadía hospitalaria en promedio fue de 1,4 días (SD ± 1,14) con 5 casos externados el mismo día del procedimiento. Conclusiones: Los procedimientos de reparación endovascular de aneurismas de la aorta con una estrategia miniinvasiva fueron factibles y seguros, ya que permitieron convertir estos procedimientos en abordajes percutáneos, con bajas tasas de complicaciones asociadas al acceso, menor tiempo quirúrgico, rápida deambulación y menor estadía hospitalaria, sin modificar la seguridad global del procedimiento. La curva de aprendizaje permitió bajar la tasa de conversiones a cirugía, así como los tiempos de deambulación.


ABSTRACT Background: Aortic aneurysms, particularly of the abdominal aorta, are still common. Since 1990, conventional surgery is no longer the only treatment option due to advances in endovascular devices and techniques. We present our results in the management of aortic aneurysms with a minimally invasive endovascular technique. Objectives: The aim of this study was to analyze the 30-day outcomes of endograft implantation in the thoracic aorta and abdominal aorta using a minimally invasive approach. Methods: Between March 2012 and April 2019, 395 consecutive endografts were implanted in the aorta, and 264 (67%) were performed using a minimally invasive approach (MIN-A). Among this group, 240 (90.9%) corresponded to abdominal endo-vascular aortic repair (EVAR) and 24 (9.1%) to thoracic endovascular aortic repair (TEVAR). Results: Technical success (TS) of the implant was achieved in 99.6% of the 264 patients and clinical success (CS) in 97.7%. Thirty-day mortality was 1.1% due to pneumonia, heart failure and chronic obstructive pulmonary disease. There were no cases of myocardial infarction, stroke or need for conversion to urgent surgical repair. Mean duration of the procedure was 62 minutes (SD ± 17). Some patients required conversion to surgical closure of the access site [20 (7%) during the first 100 cases and 7 (3%) in the final 164 patients, p = 0.05]. Three (1.1%) patients presented major bleeding requiring transfusion. Mean time to ambulation was 18 hours (SD ± 10) that significantly decreased to 13 hours after the first 100 patients (SD ± 2.9; p= 0.05). Mean length of hospital stay was 1.4 days (SD ± 1.14) with 5 patients discharged on the same day of the procedure. Conclusions: Endovascular aortic aneurysm repair using a minimally invasive strategy was feasible and safe, turning this procedure into a percutaneous approach, with low access site-related complications, shorter operative time, rapid ambulation and shorter length of hospital stay, without modifying overall safety of the procedure. The learning curve resulted in reduced rate of conversion to surgery and earlier ambulation.

4.
Tex Heart Inst J ; 44(6): 399-401, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29276439

RESUMO

Late aneurysm formation in the proximal aorta or distal aortic arch is a recognized sequela of untreated stenosis of the aortic isthmus and is associated with substantial risk of aortic rupture. We describe the case of a 44-year-old man with untreated coarctation of the aorta who presented with a prestenotic dissecting thoracic aortic aneurysm. He declined surgery because he was a Jehovah's Witness. Instead, we performed emergency endovascular aortic repair in which 2 stent-grafts were placed in the descending aorta. Our experience suggests that this procedure is a useful and safe alternative to open surgery in patients who have aneurysms associated with coarctation of the aorta.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Coartação Aórtica/complicações , Dissecção Aórtica/cirurgia , Prótese Vascular , Procedimentos Endovasculares/métodos , Testemunhas de Jeová , Adulto , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/etiologia , Angiografia , Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/etiologia , Coartação Aórtica/diagnóstico , Coartação Aórtica/cirurgia , Humanos , Imageamento Tridimensional , Masculino , Desenho de Prótese , Tomografia Computadorizada por Raios X
6.
J Thorac Dis ; 9(Suppl 6): S498-S507, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28616346

RESUMO

Surgery of both the ascending and descending aortic segments in the context of an acute aortic syndrome is one of the greatest challenges for the cardiac surgeon. In the case of surgery of the descending aorta, surgical risk increases due to the technical complexity, the required aggressive approach and because surgical indication is usually established as a result of complications and therefore involves, almost always, critically ill patients. The aging of the population is causing such surgery to be considered in an increasing number of octogenarians. The present review analyzes the available scientific evidence on the surgical indications and outcomes of these complex procedures in this population, particularly in the emergent scenario. Ascending and descending thoracic aortic diseases are reviewed separately, and the role of both the current risk scores and frailty assessments are comprehensively discussed.

7.
Hong Kong Med J ; 22(6): 538-45, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27779098

RESUMO

INTRODUCTION: The use of a proximal Palmaz stent is a well-recognised technique to treat proximal endoleak in endovascular aortic repair. This study aimed to report the effectiveness and safety of an intra-operative Palmaz stent for immediate type 1a endoleak in Hong Kong patients. METHODS: This case series was conducted at a tertiary hospital in Hong Kong. In a cohort of 494 patients who underwent infrarenal endovascular aortic repair from July 1999 to September 2015, 12 (2.4%) received an intra-operative proximal Palmaz stent for type 1a endoleak. Immediate and subsequent proximal endoleak on follow-up image was documented. RESULTS: Morphological review of the pre-repair aneurysm neck showed five conical, one funnel, five cylindrical and one undetermined short neck, with a median neck angle of 61 degrees (range, 19-109 degrees). Stent grafts used included seven Cook Zenith, one Cook Aorto-Uni-Iliac device, three Metronic Endurant, and one TriVascular Ovation. Eleven Palmaz stents were placed successfully as intended, but one of them was accidentally placed too low. Of the 12 type 1a endoleaks, postoperative imaging revealed immediate resolution of eight whilst four had improved. After a median follow-up of 16 (range, 1-59) months, none of the subsequent imaging showed a type 1a endoleak. The mean size of the aneurysm sac reduced from 7.4 cm preoperatively to 7.3 cm at 1 month, 6.9 cm at 6 months, 7.1 cm at 1 year, and 6.1 cm at 2 years postoperatively. None of these patients required aortic reintervention or had device-related early- or mid-term mortality. One patient required delayed iliac re-interventions for an occluded limb at 10 days post-surgery. CONCLUSION: In our cohort, Palmaz stenting was effective and safe in securing proximal sealing and fixation.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Endoleak/cirurgia , Complicações Pós-Operatórias/cirurgia , Stents , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Feminino , Hong Kong , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Centros de Atenção Terciária , Tomografia Computadorizada por Raios X , Resultado do Tratamento
8.
Einstein (Säo Paulo) ; 12(4): 499-501, Oct-Dec/2014. graf
Artigo em Português | LILACS | ID: lil-732463

RESUMO

O avanço tecnológico da cirurgia endovascular no tratamento de aneurismas de aorta vem permitindo que uma maior quantidade de pacientes, antes considerados inaptos para essa abordagem, beneficie-se dessa modalidade terapêutica. Apesar da atual disponibilidade de endopróteses com alta conformabilidade, casos com anatomia desfavorável permanecem um desafio para os cirurgiões. Descrevemos um caso anatomicamente desfavorável, resolvido com sucesso pela técnica endovascular, utilizando-se uma manobra não convencional.


The advances in endovascular surgery for treatment of aortic aneurysms have allowed a greater number of patients, who were previously considered unsuitable for the approach, to benefit from this therapeutic modality. Despite the current availability of highly comfortable endografts, cases with unfavorable anatomy remain a challenge for surgeons. We report a case with difficult anatomy that was successfully managed using an unconventional endovascular technique.


Assuntos
Idoso de 80 Anos ou mais , Feminino , Humanos , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular , Implante de Prótese Vascular/métodos , Aneurisma da Aorta Abdominal/patologia , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X , Resultado do Tratamento
9.
Tex Heart Inst J ; 41(2): 198-202, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24808784

RESUMO

Endovascular and open surgical repair have been used in patients with descending thoracic aortic dissection; however, the appropriate treatment is debated. We describe the case of a 60-year-old woman who had a symptomatic, chronic, residual, descending thoracic aortic dissection that was complicated by an aortobronchial fistula. She underwent emergent thoracic endovascular stent-grafting but remained symptomatic. Computed tomographic angiograms showed a contained rupture into the lower lobe of the left lung. The patient underwent definitive surgery to remove the stents, reconstruct the aorta, and resect the nonviable lung tissue. The remainder of her postoperative course was uneventful, and she was discharged from the hospital 13 days after the 2nd operation. Results of genetic testing confirmed an earlier presumptive diagnosis of Marfan syndrome. In an emergency, the best initial option for patients with a complicated descending thoracic aortic dissection might be thoracic endovascular aortic repair, which could serve as a bridge to definitive open repair.


Assuntos
Implante de Prótese Vascular , Fístula Brônquica , Remoção de Dispositivo/métodos , Pneumonectomia/métodos , Complicações Pós-Operatórias , Dissecção Aórtica/diagnóstico , Dissecção Aórtica/etiologia , Dissecção Aórtica/fisiopatologia , Dissecção Aórtica/cirurgia , Angiografia/métodos , Aorta Torácica/patologia , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/métodos , Fístula Brônquica/diagnóstico , Fístula Brônquica/etiologia , Fístula Brônquica/fisiopatologia , Fístula Brônquica/cirurgia , Doença Crônica , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Feminino , Humanos , Lesão Pulmonar , Síndrome de Marfan/complicações , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/cirurgia , Reoperação/métodos , Stents/efeitos adversos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...